Advanced RT60 Reverb Measurement
The XL2 is a precise and reliable RT60 measurement instrument. In addition to the T20 calculation, the XL2 Sound Level Meter now measures reverberation time using the T30 method. This enhancement is in line with the current ISO3382 standard and is free for all XL2 customers.
A reverberation time RT60 measurement represents the time taken for the sound level in a room to drop by 60 dB, after the sound source is suddenly removed. The XL2 employs a Schroeder reverse integration method to measure the RT60 reverberation spectrum in octave bands from 63 Hz to 8 kHz. The optional "Extended Acoustic Pack" increases the measurement resolution to 1/3rd octave bands in the range from 50 Hz to 10 kHz.
XL2 measures reverberation time in accordance with ISO3382 Standard
According to the ISO3382 standard, reverberation time can be determined using various measurement methods. The XL2 now offers two such methods; the new T30 method and the current T20 method. The procedure to measure reverberation with both methods is simple.
Read more ...
|